Otis Instruments OI-6000-X-X-X-X-X-C Sensor Assembly
Availability: In stock
Specification
Sensor Type | Electrochemical, Infrared, Photoionization Detector |
Power Voltage | Wired Powered (2-Wire) 12 to 35 VDC (Optional AC Power Supply) |
Power Draw | 2 Watts Maximum |
Protection | - Power Electromagnetic Interference (EMI) Filter |
- 4-20 mA Surge Suppression | |
- RS-485 Surge Suppression | |
Display Screen | - 102x64 Resolution Graphical LCD Screen |
- Transflective (Sunlight Readable) with White LED Backlight | |
Interface | - 3 Push-Buttons (MENU, ADD and SUB) |
- 3 Magnetic Non-Intrusive Switches for Calibration (MENU, ADD and SUB) | |
Customizable Settings | - 2 Individually-Configurable Alarm LED Set-Points |
Tamb Temperature Range | -40°C to +70°C |
Wired (Analog) Output | 4-20 mA (3-Wire) - Fault Terminal |
(Digital) Output | - RS-485 Modbus |
- Optional GEN I 900 MHz or GEN II 2.4 GHz Radio WireFree Output | |
Product Dimensions | 5" L x 5" W x 5" H |
Total Weight | 5 lbs. |
Hardware Warranty | Limited one year |
Sensor Element Warranty | Varies with Gas Type |
Enclosure Material | 1, us and 274 6 ady artonate Enclosure with Clear Window - IP 66, UL 508 and UL 746C (f1) Rated |
Product Number Formula | 0I-6000-[Sensor Type)-[Gas)-[Radio Option]-[Relay/Light Option]-[Power Supply)-C |
Description
The Otis Instruments OI-6000 Series Ambient Air Toxic Gas Detector is a versatile assembly that uses an electrochemical, infrared or PID sensor element to detect a variety of gases. Wired powered (12 to 35 VDC) with 4-20 mA analog and RS-485 Modbus outputs. Magnetic switches allow for non-intrusive calibration while in the field as well as full system settings and diagnostics.
Features
- Electrochemical, Infrared or PID Sensor clement
- Wired Powered (3-Wire), 12-35 VDC Operating Voltage, Optional AC Power Supply
- Operating Temperature Range of -40°C to +70°C
- Graphical LCD with LED Backlight
- 3 Push-Button Interface (ADD, MENU, SUB) with 3 Corresponding Magnetic, Non-Intrusive Switches
- Output Options: 4-20mA (3-Wire), Analog, RS-485 Modbus, Optional GEN II 900 MHz or GEN II 2.4 GHZ Radio
- 2 Individually Configurable Alarm Set Points; Integrated LED Lighting Systems - Configurable for RED, AMBER, BLUE, WHITE per Alarm and Fault Conditions
- Sensor Element Warranty Subject to Otis Verification
- 1-Year Limited Hardware Warranty
- Piezo Terminal Buzzer per Alarm and Fault Conditions - Piezo Terminal Can Power External Alarm Up to 500mA
Please refer to datasheet for more information
Technical Data-Sheet