Rosemount 5301 Guided Wave Radar Level transmitters
Availability: In stock
Specification
Specifications
Signal output :-
- 4-20 mA with HART communication
- RS-485 with Modbus communication
- Rosemount 2410 Tank Hub Connectivity
Housing material:-
- Polyurethane-covered Aluminum
- Stainless Steel, Grade CF8M (ASTM A743)
Conduit / cable threads:-
- ½ - 14 NPT
- M20 x 1.5 adapter
- 2 pcs M20 x 1.5 adapter
- Metal cable gland (½ - 14 NPT)
- M12, 4-pin, Male connector (eurofast®)
- A size Mini, 4-pin, Male connector (minifast®)
Materials certification:- NACE® material recommendation per ANSI/NACE MR0175/ISO 15156 and NACE MR0103
Weight assembly options for flexible single probes:- Weight or chuck not mounted on the probe
Installation options:-
- Long stud 9.8 in (250 mm) for flexible single lead probe to prevent contact with wall/nozzle. Standard stud length is 3.9 in (100 mm) for probes 5A and 5B.
- 316L SST Mounting Bracket for 1½-in. NPT Process Connection (RA)
Total probe length:- 0-164 ft or 0-50 m
Transient protection:- Transient Protection Terminal Block. Selectable with HART 4-20 mA output (output code H). Already included in all FOUNDATION Fieldbus variations.
Diagnostic functionality:-
- FOUNDATION Fieldbus Diagnostics Suite (includes Signal Quality Metrics diagnostics)
- HART Diagnostics Suite (includes Signal Quality Metrics diagnostics)
Verification reflectors (high level supervision):-
- (24) Verification reflector - 3- to 6-in. pipe/chamber (High Level Supervision
- (24) Verification reflector - 8-in. pipe/chamber (High Level Supervision)
- (24) Verification reflector - tanks and 10-in. or wider pipe/chamber (High Level Supervision)
Remote housing mounting:-
- 1 m / 3.2 ft. Remote Housing Mounting Cable and 316L SST Bracket
- 2 m / 6.5 ft. Remote Housing Mounting Cable and 316L SST Bracket
- 3 m / 9.8 ft. Remote Housing Mounting Cable and 316L SST Bracket
Safety certifications:-
- Prior-use certificate of FMEDA Data. Only available with HART 4-20 mA output (output code H)
- Safety-certified to IEC 61508 with certificate of FMEDA data. Only available with HART 4-20 mA output (output code H).
Alarm limit configuration:-
- Namur alarm and saturation levels, high alarm
- Namur alarm and saturation levels, low alarm
- Low alarm (standard Rosemount alarm and saturation levels)
Description
Rosemount 5301 Guided Wave Radar Level transmitters provide industry Leading measurement capabilities and reliability in liquids. Characteristics include:
- Direct Switch Technology and Probe End Projection to handle low reflective media And long measuring ranges
- Wide range of probe styles, materials, and temperatures and pressures forApplication flexibility
- HART 4-20 mA, F OUNDATION fieldbus, Modbus, or IEC 62591 (Wireless HART) with the Smart Wireless THUM adapter
- Prior use SIL 2 suitable (QS Option)
- Advanced Diagnostics (D01 & DA1 Options)
- Transmitter verification and high level supervision (option code HL1, HL2, or HL3)
Technical Data-Sheet